Customization: | Available |
---|---|
After-sales Service: | Online Services |
Warranty: | 3 Years |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Technical parameters of generator set:
1. Unit model: 800GF
2. Rated power: 800KW
3. The rated power factor: COS Φ = 0.8 (lag)
4. Rated output voltage: 400V/230V
5. Rated current: 1440A
6. Rated frequency: 50Hz
7. Rated speed: 1500rpm
8. Start control mode: electric start
9. Full load fuel consumption: 220g/ kW •h
10. Fuel grade :(standard) 0# light diesel oil (normal temperature)
11. Lubricating oil brand :(standard) SAE15W / 40
12. Overall dimension (mm) : 5920*2000*2900
Steady-state voltage adjustment rate: ≤±0.5%
14. Transient voltage adjustment rate: ≤-10%/+15%
15 voltage volatility (%) : ≤±0.5
16. Voltage stability time: ≤1.5sec
17. Voltage waveform distortion: ≤8%
18. Steady-state frequency adjustment: ≤3%
19. Transient frequency adjustment: ≤±5%
20. Frequency stabilization time: 3sec
21. Steady-state frequency adjustment (%) : ≤±1
22 frequency volatility (%) : ≤±0.5
23. Noise (LP1M) : 98dB (A)
Brand: Jichai lubricating oil capacity: 200L
Type: Z12V190BD Class: four stroke, exhaust gas turbocharged, direct injection compression ignition
Power rate: 882KW Cooling mode: come with fan water tank forced closed circulating water cooling
Number of cylinders: 12/V type speed regulation mode: electronic speed regulation/mechanical speed regulation
Discharge capacity: 71.45L cylinder diameter * stroke: 190mm*210mm
Start mode: DC24V electric start speed: 1500rpm
24. Weight: 13500KG
The standard configuration of the generator set is as follows:
Ø field in internal combustion engine (diesel);
Ø ac synchronous generator (single bearing);
Ø suitable environment 40 ºC to 50 ºC radiator tank, belt drive cooling fan, fan safety shield;
Ø power output air switch, standard control panel;
Steel common-base Ø unit (including: the unit vibration rubber pads);
Ø dry type air filter, fuel filter, oil filter, start the motor, and is equipped with the charging generator;
Ø start battery and battery start connecting cable;
Ø industrial muffler and connected with standard parts
Ø random data: diesel engine and generator factory technical documents, generating set manuals, test reports, etc.